How does Misting Cooling System Improve the Thermal Environment?

by cocofu
0 comment

Misting cooling systems utilize the principle of water vapor evaporation to absorb heat, thereby achieving a cooling effect. The higher the temperature and the lower the relative humidity, the greater the cooling potential of misting cooling technology becomes. Notably, misting cooling systems have been widely applied and are particularly relevant in the hot summer months when the existing outdoor thermal environment fails to meet human needs for thermal comfort outdoors. To address the discomfort caused by outdoor heat, misting cooling systems have drawn significant attention as a focus for improving comfort levels.

To mitigate the adverse effects of urban heat islands and localized overheating in cities, a variety of effective measures have been proposed, including reflective materials, green vegetation, and cool roofs. While these technologies have demonstrated specific cooling effects, they offer passive cooling. The rapid cooling effect for specific areas is relatively weak, not very pronounced, and the temporary benefits are not always apparent.

However, unlike passive measures, misting cooling systems are considered a promising active cooling technology. Experiments confirming the effectiveness of outdoor misting systems in reducing summer temperatures have ensured that these systems can effectively improve the outdoor thermal environment and enhance human thermal comfort.

Dry environments tend to benefit more from cooling effects than humid environments do. Due to the increase in indoor relative humidity, traditional residential buildings generally do not use cooling systems. However, mist cooling methods are still employed in some notable buildings, including livestock barns, greenhouses, and outdoor structures. In these unique settings, suitable air temperature and humidity are two crucial environmental parameters for the healthy growth of livestock, poultry, and plants.

Harsh high-temperature environments can lead to a sharp decrease in the survival rates of livestock and poultry due to poor insulation and low airtightness of the shelters. The application of traditional air conditioning requires high energy consumption. Therefore, misting cooling systems have become an effective means to improve the thermal environment in livestock and poultry shelters, offering a viable solution to reduce heat stress and enhance the welfare of animals and plants in various agricultural settings.

How Does Misting Cooling System Improve The Thermal Environment?


Misting cooling systems have emerged as an innovative solution to improve thermal comfort in urban public spaces, demonstrating a profound ability to enhance the microclimate through a series of carefully designed experiments. Here’s how these systems work and the impact they’ve had based on demonstrated case studies:

Working Principle

The cornerstone of misting cooling systems is evaporative cooling. These systems disperse a fine mist of water into the air. When water droplets evaporate, they absorb heat from the air, which lowers the ambient temperature. This principle harnesses the latent heat of vaporization, effectively cooling the surrounding area.

Solar Energy and Fuzzy Logic Control: Modern misting systems incorporate solar power and fuzzy logic for smarter energy use and operational efficiency. Solar panels provide a renewable energy source to power the system, while fuzzy logic controllers optimize mist release based on humidity, temperature, and solar intensity, reducing water and energy consumption.

Case Studies

  • Urban Public Spaces: Experiments have shown that misting systems can reduce air temperatures by up to 8.2°C and increase humidity by an average of 7%, significantly improving comfort levels in public spaces. The integration of solar energy and fuzzy logic allows for a reduction in energy consumption while maintaining optimal cooling and humidity levels, achieving temperature reductions between 6.14°C and 7.5°C, and managing relative humidity within the range of 51.2% to 67.5%.
  • School Rooftops: Installation of misting nozzles on a school rooftop for a week demonstrated a significant temperature decrease of 7.4°C at heights of 2.2m and 1.1m, with relative humidity increases controlled under 13%. This application highlights the system’s ability to create more comfortable outdoor learning environments.
  • Residential Areas: In residential settings, the system proved effective in lowering temperatures by 3°C within a mist radius of 3 meters, particularly beneficial when wind speeds were below 3.3m/s. This demonstrates the system’s utility in private settings, enhancing comfort during hot days.
  • Air Conditioning Efficiency: By installing misting systems around air conditioning units on rooftops and balconies, temperatures were reduced by up to 60%, and energy consumption by up to 80%. This not only improves the efficiency of the air conditioning units by reducing their cooling load but also contributes to significant energy savings.
  • Roof Cooling: Analyzing the relationship between environmental parameters and cooling effects revealed that external surface temperatures could be reduced by 4.8 to 19.5°C, and internal temperatures by 0.2 to 4.9°C. Despite significant cooling effects on roofs, the impact was not as pronounced with shading products, likely due to mist thickness and wind interference.

Equipment Performance on Cooling Misters Effect

The study of outdoor misting systems has provided valuable insights into the thermal environments both outdoors and indoors, with cooling misters being extensively researched for their capability to enhance outdoor thermal comfort and air quality. This research has led to important discoveries regarding the factors that affect their cooling performance, underscoring the significance of optimizing the performance of cooling misters by taking into account both internal and external factors.

Investigations into the internal factors of the equipment have primarily focused on control variables related to the nozzle itself. These include the type of nozzle, water pressure, nozzle diameter, droplet size, nozzle height, and the angle of spray. Optimizing these parameters is crucial for maximizing the effectiveness of misting systems in reducing temperatures and enhancing comfort levels.

External factors that influence the performance of misting systems are closely tied to environmental conditions such as air temperature, relative humidity, wind speed, and solar radiation. Understanding the impact of these external conditions on the cooling effect of misting systems is essential for enhancing their efficiency and effectiveness across various settings.

By addressing both the internal characteristics of misting systems and the external environmental conditions, the operational performance of cooling misters can be significantly improved. This holistic approach enables the strategic implementation of misting systems to ameliorate the thermal environment outdoors and, indirectly, indoors as well, contributing to the creation of more comfortable and healthier living and working spaces.

Nozzle Diameter and Nozzle Type

The nozzle diameter and type are crucial factors in the design and efficiency of misting cooling systems. They significantly influence the size of the water droplets produced, the distribution of the mist, and ultimately, the system’s overall cooling effectiveness. Understanding these elements can help optimize a misting system for specific applications, from outdoor cooling to humidification and even agricultural uses.

Nozzle Diameter

The nozzle diameter affects the velocity and size of the water droplets ejected from the nozzle. Smaller diameters generally produce finer mist with smaller water droplets, which can evaporate more quickly and efficiently, enhancing the cooling effect. However, smaller diameters may also lead to quicker clogging if the water is not adequately filtered, requiring more maintenance.

  • Larger Diameters: Tend to produce larger droplets that might not evaporate as quickly, potentially leading to wetness in the misted area. They are better suited for applications where immediate evaporation is not critical, such as in certain agricultural settings or when the primary goal is direct cooling or humidification without concern for residual moisture.

  • Smaller Diameters: Ideal for applications requiring rapid evaporation and a significant cooling effect without wetting surfaces, such as outdoor human comfort or cooling sensitive equipment.

Nozzle Type

The type of nozzle influences the mist’s pattern, distribution, and droplet size, affecting the system’s suitability for different environments and purposes.

  • Impingement Nozzles: These nozzles force water through a small orifice, producing a fine mist. They are commonly used in cooling systems due to their efficiency in creating small droplets that evaporate quickly.

  • Ultrasonic Nozzles: Use high-frequency sound waves to produce extremely fine droplets, ideal for applications requiring rapid evaporation. These nozzles are highly efficient but can be more expensive and are typically used in specialized applications, such as precise humidity control in greenhouses or laboratories.

  • Fog Nozzles: Designed to create a dense fog, these nozzles are suitable for applications needing high humidity levels or where the cooling effect needs to be maximized through a large surface area of droplets.

  • Rotary Nozzles: Utilize centrifugal force to eject water droplets, producing a fine mist with varying droplet sizes. These are often used in agricultural applications for both cooling and irrigation.

Choosing the right nozzle diameter and type depends on the specific requirements of the cooling application, including the desired cooling effect, the environment’s humidity levels, and whether minimal residual moisture is a priority. Balancing these factors ensures that the misting system operates efficiently, providing the necessary cooling or humidification while minimizing water usage and maintenance needs.

Nozzle Water Pressure

Nozzle water pressure is a pivotal factor in the operation and effectiveness of misting cooling systems. The pressure at which water is forced through the nozzle impacts the mist quality, droplet size, and the distance the mist can travel before evaporating. Understanding the role of water pressure can help in optimizing a misting system for specific environmental conditions or applications.

Influence of Water Pressure on Misting Systems

  • Droplet Size: Higher water pressures typically produce smaller water droplets, which evaporate more quickly. This is crucial for cooling applications where rapid evaporation is needed to reduce temperatures without leaving residual moisture. Conversely, lower pressures result in larger droplets, which may not evaporate as swiftly and could cause dampness in the area being cooled.

  • Cooling Efficiency: The efficiency of a misting system in cooling an area increases with the pressure, thanks to the production of finer mist that can cover a larger area and evaporate more rapidly, absorbing more heat from the environment.

  • Range and Coverage: Higher pressures can also increase the mist’s range, allowing the system to cover a larger area. This is particularly useful in outdoor or large indoor spaces where extensive coverage is necessary for effective cooling.

  • System Requirements and Costs: Operating a misting system at higher pressures requires more robust and, often, more expensive equipment, including high-pressure pumps and nozzles designed to withstand the stress of high water pressures. This can increase the initial and operational costs of the system.

Water Pressure Categories in Misting Systems

  • Low Pressure (around 30 to 50 psi): Low-pressure systems are simpler and less costly but produce larger droplets that may not evaporate completely in hot conditions, potentially causing wetness.

  • Medium Pressure (around 100 to 250 psi): Medium pressure systems strike a balance between efficiency and cost, producing a finer mist than low-pressure systems without the high costs associated with high-pressure systems. They are suitable for residential and light commercial applications.

  • High Pressure (above 800 psi): High-pressure misting systems are the most efficient at cooling, as they produce the finest mist for rapid evaporation. While they offer the best cooling performance, they are also the most expensive due to the need for specialized pumps and nozzles that can handle the high pressure.

Considerations for Choosing Water Pressure

Selecting the appropriate water pressure for a misting system involves considering the specific needs of the application, including the desired cooling effect, the environment (outdoor vs. indoor, humidity levels), and budget constraints. High-pressure systems are ideal for applications where maximum cooling and quick evaporation are critical, such as in dry, hot climates or in settings where maintaining minimal moisture levels is essential. Medium and low-pressure systems may be more suitable for more humid environments or applications where some moisture residue is acceptable and budget limitations are a consideration.

Nozzle Height

Nozzle height in a misting cooling system plays a significant role in determining the system’s effectiveness in cooling and coverage area. The height at which nozzles are installed affects how the mist is dispersed, how quickly it evaporates, and ultimately, the cooling effect on the immediate environment. Proper consideration of nozzle height can enhance the performance of a misting system for various applications, from outdoor patios to greenhouse environments.

Importance of Nozzle Height

  • Evaporation Distance: Higher nozzle installations allow more time for the mist droplets to evaporate before reaching the ground or surfaces. This is crucial for cooling applications, as the cooling effect of a misting system is primarily achieved through the evaporation of water droplets, which absorbs heat from the air.

  • Coverage Area: The height of the nozzle also impacts the coverage area of the mist. Higher installations can disperse mist over a wider area, but the effectiveness of cooling may vary depending on wind conditions and the size of the water droplets. Conversely, lower nozzle heights can concentrate the cooling effect but with a reduced coverage area.

  • Wind Influence: The effectiveness of a misting system can be significantly affected by wind. Higher nozzle installations are more susceptible to wind, which can carry the mist away from the desired cooling area, potentially reducing the system’s efficiency. Strategic placement and consideration of typical wind patterns are crucial when deciding on nozzle height.

  • Human Comfort and Safety: For applications such as outdoor patios or dining areas, nozzle height must be optimized to ensure human comfort. Nozzles should be placed high enough to allow for complete evaporation before the mist reaches occupants, preventing wetness and discomfort. Additionally, installing nozzles out of reach ensures safety and prevents accidental damage to the system.

Recommended Nozzle Heights

The optimal nozzle height varies based on application, environmental conditions, and the specific setup of the misting system. However, some general recommendations include:

  • Outdoor Cooling (e.g., patios, dining areas): Nozzles should be installed at a height of about 8 to 10 feet above the ground. This height allows for effective area coverage while ensuring mist evaporation before it comes into contact with individuals or surfaces.

  • Agricultural and Greenhouse Applications: The recommended height can vary significantly depending on the crop type, greenhouse design, and desired humidity levels. It’s essential to customize the system based on specific horticultural needs.

  • Industrial and Special Applications: In settings such as warehouses or outdoor events, nozzle height will depend on the area’s size, the volume of people present, and the specific cooling requirements. Professional consultation is recommended to design an optimal system configuration.

In all cases, the effectiveness of a misting system can be maximized by considering not only the nozzle height but also other factors such as nozzle type, water pressure, and environmental conditions. Adjustments and optimizations should be made based on specific needs and observed performance to achieve the desired cooling effect

Droplet Diameter Size

Droplet diameter size in a misting system is a crucial factor that significantly influences the efficiency and effectiveness of the cooling process. The size of the droplets affects how quickly they evaporate, the potential for residual moisture, and the overall cooling capacity of the system. Understanding how droplet size impacts misting performance can help in optimizing the system for various applications, from outdoor cooling to industrial processes.

Importance of Droplet Size

  • Evaporation Rate: Smaller droplets have a larger surface area relative to their volume, which enhances the evaporation rate. Rapid evaporation is essential for effective cooling because it allows the heat to be absorbed from the environment more quickly. This is particularly important in hot and dry climates where the cooling effect needs to be maximized without leaving moisture behind.

  • Residual Moisture: Larger droplets are slower to evaporate and are more likely to settle on surfaces and create wetness. This can be undesirable in areas where dry conditions are necessary to prevent slip hazards or protect sensitive equipment. In contrast, smaller droplets are ideal for applications requiring a dry atmosphere after cooling.

  • Cooling Effectiveness: The effectiveness of cooling depends largely on how completely the droplets can evaporate before they contact surfaces. Smaller droplets provide a more consistent and effective cooling effect over a larger area, especially when used in conjunction with high-pressure systems that produce a fine mist.

Factors Influencing Droplet Size

The size of the droplets produced by a misting system is determined by several factors:

  • Nozzle Design: Different types of nozzles produce different droplet sizes. For example, impingement nozzles typically produce smaller droplets compared to other types, such as rotary or ultrasonic nozzles.

  • Water Pressure: Higher pressures generally result in smaller droplets as the water is forced through the nozzle at a higher velocity, breaking it into finer particles.

  • Nozzle Orifice Size: The diameter of the nozzle orifice also plays a critical role. Smaller orifice sizes tend to produce smaller droplets, while larger orifices produce larger droplets.

Recommended Droplet Sizes

  • Outdoor Cooling and Humidification: For applications such as patio cooling or outdoor events, droplet sizes in the range of 10-30 microns are typically recommended. These sizes ensure rapid evaporation, which maximizes cooling without significant residual moisture.

  • Greenhouses and Agriculture: In agricultural settings, such as greenhouses, droplet sizes may vary based on the specific humidity and irrigation needs. Slightly larger droplets might be preferred to ensure adequate water delivery to plants without over-saturating the environment.

  • Industrial Applications: For industrial cooling or dust suppression, droplet sizes will depend on the specific requirements of the process. For dust control, larger droplets might be necessary to effectively capture and settle dust particles.

In conclusion, selecting the appropriate droplet size is essential for maximizing the performance of a misting system. It requires careful consideration of the specific application, environmental conditions, and the desired outcome, whether it’s cooling, humidification, or dust control. Adjustments in nozzle type, water pressure, and orifice size are all critical in achieving the optimal droplet diameter for any given application.

How to Improve The Efficiency of Cooling Misters

In high-humidity areas, water evaporates slowly in outdoor misters, making it difficult to achieve an effective cooling effect. Therefore, adding some easily evaporated liquids to the water can improve the phase change heat absorption capacity, accelerate the heat absorption process from liquid to gaseous state, and thereby improve the performance of cooling misters. Effect,

The factors of the outdoor environment are more complex. The mist droplets often cannot accurately land on the surface of the human body to achieve cooling, or a large number of mist droplets are concentrated in one place, causing an uncomfortable feeling of humidity. To address this problem, we added fans and cooperated with outdoor misters to form a Misting fans can accurately land misters at fixed points, allowing misters to absorb heat and cool down while sending mist droplets to their destination. In a country like Singapore with high temperatures and high relative humidity all year round,

The misting fans system can be turned on only when the test performance temperature set value reaches 29.2°C. This ambient temperature set value is affected by the environment and climate zone, and requires specific analysis based on the climate zone and meteorological environment of the region.If air misters are used to analyze the amount of misters and the cooling effect, the wind is used to drive the droplets to move to farther areas to achieve the effect of accelerating droplet evaporation and cooling. At the same time, increasing the water flow under misting fans will enhance the cooling effect, and with time As the wind speed increases, the range covered by misters increases, further expanding the cooling area.

The continuous operation of cooling misters will not only damage the life of the machine and increase power consumption, but also affect the thermal comfort of the human body due to the continuous accumulation of relative humidity. Therefore, cooling misters require a suitable control system. Feasibility and economic benefits of using fixed misting cooling system and mobile misting cooling system.

The results show that the fixed misting cooling system has good economic benefits in terms of construction cost, operation cost, maintenance cost, etc. It is the future development trend to use renewable energy to continuously supply the power required for the equipment of the misting cooling system.